PSL Handler Update System


About

The PSL Handler Update System is designed to replace the original server hosted by Radionics Inc to update handlers in the D5200 programmer.

This system operates just like the original, and is open for alarm technicians to use for updating the handlers in their programmers. Please note that downloading handlers from this server takes longer than the original one did. We did not have access to the original server at the time that we had reversed the protocol, so we are not able to transfer the handlers without the database being included in them. This does not affect the operation of the handler, it only makes it take longer to download the handler from the server.


Downloading Handlers

To download a handler to your programmer, follow the steps below:

  1. Connect the TELCO jack on your D5200 programmer to an analog phone line (VoIP lines may not work reliably as their compression does not handle modem connections very well)
  2. From the main menu on the programmer, scroll to the UPDATE option and press ENTER GROUP
  3. Under the "HandName" field, enter the name of the handler you wish to download and press ENTER
  4. Under the "Include Help" field, use SPACE to scroll to "No" and press ENTER
  5. Under the "Phone" field, enter "13044517092" and press ENTER twice
  6. Under the "Mode" field, use SPACE to scroll to "TELCO->A" (or "TELCO->B" for downloading to a RAM card) and press ENTER

The programmer will now pick up the phone line and use pulse dialing to call the handler update system. After the download process has been completed the programmer will display "UPDATE SUCCESSFUL" and you will have the new handler available for use. If the call does not go through the first time, try again in a little while, the server can currently only answer one call at a time.

If your programmer displays "HANDLER NOT FOUND" when trying to download a handler, first make sure that the handler name is typed properly, and the handler is listed in the available handlers below. If those are both correct, use the "DELETE" menu to delete the handler (even if it's not showing in the list) and then try the update again. Sometimes this process needs to be done if the handler was previously on the programmer, or was corrupted.


Handler List

Type Handler Name Size (Blocks) Version Source
Radionics 9000MAIN 292 01.15 Brian Mulka
Radionics RADXPNTS 131 01.04 Alarmco, Inc
Radionics RADXUSR1 147 01.03 Alarmco, Inc
Radionics RADXUSR2 147 01.02 Alarmco, Inc
Radionics RADXSKED 188 01.02 Brian Mulka
Radionics RADXAXS 100 01.04 Brian Mulka
Radionics RADXAUX1 116 01.06 Brian Mulka
Radionics GV2MAIN 308 01.04 Norb Friedrich
Radionics GV2AUX 122 01.03 Norb Friedrich
Radionics 6500 99 01.41 Norb Friedrich
Radionics 636 59 01.00 Brian Mulka
Radionics 2071 59 01.00 Brian Mulka
Radionics 2012 179 01.04 Alarmco, Inc
Radionics 2112 131 01.30 Brian Mulka
Radionics 2212 171 01.30 Alarmco, Inc
Radionics 4112 91 04.50 Brian Mulka
Radionics 6112 107 02.10 Norb Friedrich
Radionics 7112 195 02.00 Brian Mulka
Radionics 8112 371 02.60 Brian Mulka
Radionics 7212B 291 02.00 Brian Mulka
Radionics 9112B 299 02.00 Brian Mulka
Honeywell 5501 100 01.40 Norb Friedrich
Honeywell 5503 107 01.20 Norb Friedrich
Honeywell 5505 283 01.00 Norb Friedrich
Honeywell 5600 171 00.04 Norb Friedrich
Honeywell 5700 212 03.00 Norb Friedrich
Honeywell 5800B 363 01.00 Norb Friedrich
Honeywell 5900B 356 01.00 Norb Friedrich
Honeywell 5900MAIN 284 01.25 Norb Friedrich
Honeywell ACCESS 100 01.04 Norb Friedrich
Honeywell POINTS 156 01.05 Norb Friedrich
Honeywell SKEDS 180 01.18 Norb Friedrich
Honeywell USERS1 188 01.01 Norb Friedrich
Honeywell USERS2 187 01.07 Norb Friedrich